MANAGING THE COOLING OF YOUR SERVER ROOM OR DATA CENTRE KEEPING YOUR DATA
AT THE RIGHT TEMPERATURE & HUMIDITY
CAN BE A TRICKY OPERATION.

HIGH WALL MOUNTS, CEILING MOUNTED, FLOOR MOUNTED OR DUCTED SYSTEM, WE HAVE A DATACENTER OR SERVER ROOM
COOLING SOLUTION FOR YOU.


COMMS ROOM COOLING DATACENTER/SERVER ROOM COOLING
DATA CENTRE COOLING
datacenter cooling
SERVER ROOM COOLING
Below you will find a guide allowing you to get an indication of what size system you will possibly require for cooling your server room/datacenter. Please remember this just an indication, for an exact calculation please call us on the number above.

There are several factors you have to take in to account when sizing for the cooling of a datacenter or server room, e.g.
  • Size of the room.
  • Total consumption rating of all equipment in the datacenter.
  • What type of lighting you have in the datacenter.
  • Allowing for future expansion of I.T equipment.
  • Maximum expected number of occupants that will be in the room at any one time for an extended period of time.
Server room cooling with the Fujitsu Floor/Ceiling system
Room size
The size of the room has a lot to do with how many kW/BTUs you will need to employ to cool down your server room or datacenter, you will need to know the volume size of the server room, (width x length x height) then times this by 0.1, this will give you the kW needed for cooling the the room (times this by 3414 to get the btu's. kW x 3414)
 
Equipment in the datacenter
As equipment gets faster, more powerful, larger storage, etc. it also gets hotter. Switches, routers, SANs, and severs all generate large amounts of heat. Hard drives and processors both generate large amounts of heat. Luckily, units that generate a lot of heat are also the ones that consume a lot of power. This makes the calculation significantly easier since you can use the wattage to calculate the power consumption of equipment. It is best to judge from the total consumption rating on your server, SAN, switch, or router instead of using actual consumption. Otherwise, during peak times the datacenter runs the risk of overheating. Convert the watts to kW (times this by 3414 to get the btu's. kW x 3414) & add this to the kW total from your room size.
 
Lighting in the datacenter
If your server room or datacenter is well lit, it is also important to take the heat that is generated from these lights into consideration. Lighting generates a noticeably higher amount of heat per watt of power consumption. Use this equation to determine total BTU output from lighting.
Convert the watts to kW (times this by 4250 to get the btu's. kW x 4250) & add this to your total.
 
Allowing for future expansion of I.T equipment.
It is important to consider future expansion, and be prepared for it. Buying a cooling unit for the current equipment and having plans to put in several more racks full of servers would not be a good idea. It would probably require buying a whole new cooling unit, or some alternative small cooling unit. It is also important to consult with an expert before making a purchase on anything that is mission critical.
 
Maximum expected number of occupants.
While many datacenters and server rooms rarely see occupants on the server floor, it can be important to take note of if there is support staff involved with the servers. Calculate from the maximum expected number of occupants that will be in the room at any one time for an extended period of time.
Occupants x 0.125 = kW from people. (times this by 3414 to get the btu's. kW x 3414) & add this to your total.
 

Total kW/btu of your datacenter/Server room
To calculate the total kW/BTU of your datacenter or server room, add all the above calculations together the total is the size of required.

You may also want to consider other sources of heat that might be unique to your datacenter.

THE SYSTEMS BELOW ARE SUITABLE FOR MOST DATACENTRE/SERVER ROOMS

DATACENTER COOLING
SERVER ROOM COOLING


HIGH WALL MOUNTS
 
'A' Rated heaters with white finish front panel, 2.6kW, 3.5kW & 5.4kW systems available

PRICES FOR THE 'VAILLANT VAi' RANGE START FROM
£315.00 + VAT

Energy rated ‘A’ in both heating and cooling modes,. We believe these excellent quality beautifully finished units are the best value systems available in the UK today.

They come with a Full 2 YEARS ON SITE manufacturers warranty, which no other manufacturer can compete with, giving you complete peace of mind.

TO VIEW ALL HIGH WALL MOUNTED SYSTEMS CLICK HERE >>>

 


DUCTED SYSTEMS
 
Fujitsu Ducted system
  • Compact unit
  • Industry leading noise reduction
  • High efficiency turbo fan
  • 7 day wired controller
  • Optional Remote controller
  • Condensate lift pump
  • Two stage turbo fan
  • Ozone friendly R410A Refrigerant
  • Auto restart
  • Low ambient Heating
  • Minimum Temperature control
  • Self fault diagnosis
  • Fresh air ventilation option
  • 3 years Parts warranty

One ducted system can easily be used to provide the heating & cooling for several office rooms, with the added advantage that no indoor unit or pipe work will be on show.

Simply install the unit above the ceiling area and duct through to air grills & vents into each room.

The 'A' Rated systems are on the ECA list.

VIEW THIS SYSTEM & OTHER DUCTED SYSTEMS >>>

 
 
FLOOR MOUNTED
 
Fujitsu Floor/Ceiling system

An intelligent approach to air conditioning with a single unit that is equally at home standing upright as a floor unit or fitted horizontally to the ceiling. The indoor units can also be semi-inserted into a false ceiling by as as much as 150mm with 140mm of the unit visible.

Either choice provides the user with a slim, lightweight air conditioner that employs Double Auto Awing louvre technology that distributes air evenly throughout the room whether at floor or ceiling height. The newly developed Super Vane feature boosts air flow throughout the room by directing air to all corners of the room.

VIEW THIS SYSTEM & OTHER FLOOR/CEILING SYSTEMS >>>

 


CEILING CASSETTES
 
4-Way blow 5kW cassette
  • Compact white unit
  • Remote controller
  • Optional 7 day wired controller
  • Two stage turbo fan
  • Ozone friendly R410A Refrigerant
  • Auto restart
  • Low ambient Heating
  • Self fault diagnosis
  • 2 years Parts warranty

These ceiling cassettes all fit neatly into a 600 * 600 ceiling tile and at only 255mm deep they need little space above the ceiling.
We believe these are the best price ceiling cassettes available in the UK today.

They are built with the reliability of Toshiba components, They have 4 way blow and the option of a hard wire controller.

FlexiQuik pipes and our preparation service are available to make installation of this product as easy as possible.

VIEW THIS SYSTEM & OTHER CEILING CASSETTE SYSTEMS >>>

 

 


 
We accept these credit cards
The Refcom Register of Companies Competent to Handle Refrigerants was set up in 1994 in response to atmospheric damage caused by certain refrigerant gases.
Hitachi Air Conditioning FG Eurofred Fujitsu Air Conditioning Vaillant Air Conditioning